Cytiva Biacore T200 SPR Biosensor Analyser

Cytiva · Biacore T200 · 2015 · ref ML-474DB146

Price

Price on quote

Custom configuration. Final price on quote only.

We plant a tree for every item sold

Description

About this model

Four-flow-cell surface plasmon resonance system for label-free kinetics, affinity, concentration and thermodynamics, from small molecules to large proteins. Single-needle design with one 96- or 384-well plate.

This unit

GE Healthcare Biacore T200 surface plasmon resonance processing unit, manufactured in Sweden in 2015, serial 1943051. The T200 has four flow cells and measures label-free kinetics, affinity, concentration and thermodynamics, from small molecules to large proteins, with up to 48 hours of unattended runs from a 96- or 384-well plate. Configuration: - Biacore T200 processing unit, serial 1943051 Condition and testing: Used. Software and computer: The control PC and Biacore T200 Control and Evaluation Software are not listed as included. The software runs on a Windows 10 64-bit PC with two RS-232 ports.

Equipment History & Condition

Used; manufactured 2015 in Sweden. Ships from the USA.

What's Included

Biacore T200 processing unit

Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.

Specifications

Condition
Good
Year Manufactured
2015
Manufacturer
Cytiva
Model
Biacore T200
KD
Weak interactions with KD in the mM range
Ka
Proteins: 10^3 to 3 × 10^9 M-1s-1; LMW molecules: 10^3 to 5 × 10^7 M-1s-1
Kd
10^-5 to 1 s-1
Power
Processing Unit: Autorange 100 to 240 VAC, 50 to 60 Hz, Class 1 equipment. Power consumption: Processing Unit: 4.0 A
Recovery
1.5 µL analyte recovery volume
Detection
Surface Plasmon Resonancebiosensor
Automation
48 h unattended operation
Flow Cells
Four
Mw Detection
No lower limit for organic molecules
Baseline Drift
Typically < 0.3 RU/min
Baseline Noise
Typically < 0.03 RU
Buffer Selector
Automatic switching between four buffers
Flow Rate Range
From 1 to 100 µL/min
Flow Cell Height
40 µm
Flow Cell Volume
0.06 µL
Injection Volume
2 to 350 µL
Analysis Temperature
4°C to 45°C
Instrument Weight Kg
60
Operating Conditions
Operation 18°C to 33°C; relative humidity 20% to 80%, non-condensing; altitude up to 2000 m. Bench area 65 x 65 cm plus approx. 60 x 60 cm for the computer; at least 20 cm clearance on all sides.
Sample Concentration
> 1 pM
Instrument Dimensions
[object Object]
Required Sample Volume
Injection volume plus 20 to 50 µL
Software Compatibility
Biacore T200 Control and Evaluation Software; result files also open in Biacore Insight Evaluation Software. Optional Biacore T200 GxP Package. OS: Windows 10 Professional or Enterprise, 64-bit. Minimum PC: 3.0 GHz processor, RAM > 1 GB free, HDD > 2 GB free, graphics at least 1280 × 1024, 2 RS-232 ports.
Sample Refractive Index
1.33 to 1.40
Sample Storage Temperature
4°C to 45°C

Shipping & Logistics

MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.

  • MerkaLoop coordinates all logistics
  • Shipping quoted before payment
  • Ships globally

Shipping from: United States

It is your responsibility to check local regulations and requirements for the handling, acceptance, and servicing of secondhand and new equipment.

contact MerkaLoop about this equipment

Similar Equipment