Acea Biosciences NovoCyte 2000 Flow Cytometer

Acea Biosciences · Biosciences NovoCyte 2000 Flow Cytometer · 2015 · ref ML-59E8C5FD

6-Month Seller Warranty

Price

€38,499

+VAT where applicable

We plant a tree for every item sold

Description

Address the full range of current and future multi-parameter cellular analysis research needs with the NovoCyte flow ​cytometer. ACEA brings researchers high performance flow cytometry at a low investment cost with the NovoCyte platform. Lasers: Blue 488 nm, Red 640 nm Detectors: 530, 585, 675 nm Laser Configuration: Spatially separated beams with 10 x 80 μm elliptical spots Optical Alignment Procedure: Fixed, no operator alignment required Flow Cell: 170 x 290 μm rectangular quartz flow cell FSC/SSC Resolution: FSC < 0.5 μm, SSC < 0.2 μm Cell Size: 0.2 – 50 μm Fluorescence Threshold Sensitivity: FITC < 75 MESF, PE < 50 MESF Fluorescence Resolution: < 3% CV for CEN Filters: User Exchangeable Sample Acquisition Rate: 35,000 events/second Volumetric Absolute Count Precision: CV < 5% Sample Flow Rate: 5 – 120 μL/min Sheath Flow Rate: 6.5 mL/min Sample Aspiration Volume: 10 – 100 μL Fluid Container Capacity: 3 L sheath, 3 L waste, 500 mL cleaning, 500 mL decontamination Carryover: < 0.1% Fluidics Maintenance: Automated startup, cleaning, decontamination and shutdown Manual Sample Loading: 12 x 75 mm tube Dimension (WxDxH): 600 x 450 x 390 mm Weight: 39 k

Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.

Specifications

Condition
Good
Year Manufactured
2015
Manufacturer
Acea Biosciences
Model
Biosciences NovoCyte 2000 Flow Cytometer
Equipment weight
48.8 kg
Equipment dimensions
60 × 39 × 45 cm
Lasers
Blue 488 nm, Red 640 nm
Filters
User Exchangeable
Warranty
6 months
Carryover
< 0.1%
Cell Size
0.2 – 50 μm
Detectors
530, 585, 675 nm
Flow Cell
170 x 290 μm rectangular quartz flow cell
Dimension Wxdxh
600 x 450 x 390 mm
Sample Flow Rate
5 – 120 μL/min
Sheath Flow Rate
6.5 mL/min
Fsc Ssc Resolution
FSC < 0.5 μm, SSC < 0.2 μm
Laser Configuration
Spatially separated beams with 10 x 80 μm elliptical spots
Fluidics Maintenance
Automated startup, cleaning, decontamination and shutdown
Manual Sample Loading
12 x 75 mm tube
Fluorescence Resolution
< 3% CV for CEN
Sample Acquisition Rate
35,000 events/second
Fluid Container Capacity
3 L sheath, 3 L waste, 500 mL cleaning, 500 mL decontamination
Sample Aspiration Volume
10 – 100 μL
Optical Alignment Procedure
Fixed, no operator alignment required
Fluorescence Threshold Sensitivity
FITC < 75 MESF, PE < 50 MESF
Volumetric Absolute Count Precision
CV < 5%

Shipping & Logistics

MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.

  • MerkaLoop coordinates all logistics
  • Shipping quoted before payment
  • Ships globally

Shipping from: Netherlands

It is your responsibility to check local regulations and requirements for the handling, acceptance, and servicing of secondhand and new equipment.

contact MerkaLoop about this equipment

Similar Equipment