Cytiva Xuri W25 Cell Expansion System
Cytiva · Xuri W25 · 2021 · ref ML-C0FB8247
Description
The Xuri Cell Expansion System W25 delivers an automated, controlled expansion environment for the growth of cell therapies in volumes up to 25 L across research, process development, and manufacturing operations. Closed system minimizes risk of cell contamination. High cell densities through automated perfusion protocols. Processes stay in control through advanced control capabilities and remote operation/monitoring via UNICORN software. Suitable for use in a regulated environment. Achieve >10 x 10⁶ cells/mL, in volumes up to 25 L, with non-invasive mixing, media perfusion, and efficient oxygen transfer in a low-sheer environment. External air supply (per CBCU): 1.0 to 1.5 bar, Normal use: 1.3 L/min, Fast fill: 3.5 L/min External CO2 supply (per CBCU): 1.0 to 1.5 bar, Normal use: 0.2 L/min, Fast fill: 0.5 L/min External O2 supply (per CBCU): 1.0 to 1.5 bar, Normal use: 0.7 L/min, Fast fill: 1.7 L/min Rocker specifications Rocking speed control range: 2 to 40 rpm Rocking angle control range: 2° to 12° Rocking speed profile range: 15% to 100% (The % value refers to the fraction of the angular displacement function that is sinusoidally shaped 15% gives an almost constant angular velocity 100% gives a sinusoidal rocking) Media weight control range: 0.5 to 25 kg Scale, absolute accuracy (single mode): ±(0.050 + 1% of load) kg Temperature sensor: Pt100 Class A Temperature measurement range: 2°C to 50°C Temperature setpoint difference: Max 10°C at ambient 21°C (The setpoint difference is reduced by 1°C for every degree centigrade that is increased from ambient temperature (e.g., at ambient 25°C, max setpoint difference is 6°C)) Temperature control range: (Ambient temperature + 5°C) to 40°C Temperature control accuracy (excl. measurement error): ±0.2°C CBCU specifications Gas flow control range: 50 to 1000 mL/min Total gas flow accuracy (reference flow – setpoint): ±(10 + 3% of read value) mL/min Fast fill flow: ~3 L/min CO2 control range: 0% to 15% CO2 CO2 measurement accuracy at 5% CO2: ±0.5% CO2 when mixed only with air/N2 CO2 control accuracy (versus setpoint): ±0.4% CO2 O2 control range: 0% to 50% O2 when mixed with N2, 21% to 50% O2 when mixed with air O2 measurement accuracy: ±(0.6 + 1% of read value) within 0% to 50% O2, when mixed only with air/N2 O2 control accuracy (versus setpoint): ±0.6% O2 pH measurement range: pH 4.5 to 8.5 pH control range: pH 6.0 to 8.0 pH measurement accuracy: ±0.05 pH within ±0.25 pH from offset calibration pH, ±0.1 pH within 0.25 to 0.5 pH from offset calibration pH pH control accuracy (versus setpoint): ±0.05 pH DO measurement range: 0% to 250% air saturation DO measurement accuracy: ±5% air saturation, excluding atmospheric pressure variations DO control range: 0% to 100% air saturation Pump specifications Pump flow rate range: 0.1 to 144 L /day (0.07 to 100 mL/min) Pump flow rate accuracy: ±(0.1 + 5% of read value) mL/min after calibration Accumulated pumped volume accuracy: ±10% of measured volume Supported tubing dimensions: Inner diameter 0.5 to 4.8 mm (1/50″ to 3/16″), Wall thickness 1.6 mm (1/16″) Dimensions rocker (WxHxD): 404 x 205 x 560 mm Dimensions CBCU (WxHxD): 276 x 117 x 360 mm Dimensions pump (WxHxD): 275 x 115 x 280 mm Weight rocker: 24 kg Weight CBCU: 4.8 kg Weight pump: 3.8 kg Excluding software
Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.
Specifications
- Condition
- Good
- Year Manufactured
- 2021
- Manufacturer
- Cytiva
- Model
- Xuri W25
- Equipment weight
- 24 kg
- Equipment dimensions
- 27.5 × 11.5 × 28 cm
- Warranty
- 6 months
- Weight Cbcu
- 4.8 kg
- Weight Pump
- 3.8 kg
- Weight Rocker
- 24 kg
- Fast Fill Flow
- ~3 L/min
- Do Control Range
- 0% to 100% air saturation
- O2 Control Range
- 0% to 50% O2 when mixed with N2, 21% to 50% O2 when mixed with air
- Ph Control Range
- pH 6.0 to 8.0
- Co2 Control Range
- 0% to 15% CO2
- Temperature Sensor
- Pt100 Class A
- Do Measurement Range
- 0% to 250% air saturation
- Ph Measurement Range
- pH 4.5 to 8.5
- Pump Flow Rate Range
- 0.1 to 144 L /day
- Dimensions Cbcu Wxhxd
- 276 x 117 x 360 mm
- Dimensions Pump Wxhxd
- 275 x 115 x 280 mm
- Gas Flow Control Range
- 50 to 1000 mL/min
- Dimensions Rocker Wxhxd
- 404 x 205 x 560 mm
- Do Measurement Accuracy
- ±5% air saturation, excluding atmospheric pressure variations
- O2 Measurement Accuracy
- ±within 0% to 50% O2, when mixed only with air/N2
- Ph Measurement Accuracy
- ±0.05 pH within ±0.25 pH from offset calibration pH, ±0.1 pH within 0.25 to 0.5 pH from offset calibration pH
- Pump Flow Rate Accuracy
- ±mL/min after calibration
- Temperature Control Range
- to 40°C
- Media Weight Control Range
- 0.5 to 25 kg
- External O2 Supply Per Cbcu
- 1.0 to 1.5 bar, Normal use: 0.7 L/min, Fast fill: 1.7 L/min
- Rocking Angle Control Range
- 2° to 12°
- Rocking Speed Control Range
- 2 to 40 rpm
- Rocking Speed Profile Range
- 15% to 100%
- Supported Tubing Dimensions
- Inner diameter 0.5 to 4.8 mm, Wall thickness 1.6 mm
- External Air Supply Per Cbcu
- 1.0 to 1.5 bar, Normal use: 1.3 L/min, Fast fill: 3.5 L/min
- External Co2 Supply Per Cbcu
- 1.0 to 1.5 bar, Normal use: 0.2 L/min, Fast fill: 0.5 L/min
- Temperature Measurement Range
- 2°C to 50°C
- Co2 Measurement Accuracy At 5 Co2
- ±0.5% CO2 when mixed only with air/N2
- Accumulated Pumped Volume Accuracy
- ±10% of measured volume
- O2 Control Accuracy Versus Setpoint
- ±0.6% O2
- Ph Control Accuracy Versus Setpoint
- ±0.05 pH
- Scale Absolute Accuracy Single Mode
- ±kg
- Co2 Control Accuracy Versus Setpoint
- ±0.4% CO2
- Temperature Setpoint Difference Dual Mode
- Max 10°C at ambient 21°C)
- Scale Left Right Absolute Accuracy Dual Mode
- ±kg
- Total Gas Flow Accuracy Reference Flow Setpoint
- ±mL/min
- Date Of Manufacture
- 2021
- Temperature Setpoint Difference
- Max 10°C at ambient 21°C)
Shipping & Logistics
MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.