Beckman Coulter Navios Flow Cytometer
Beckman Coulter · Coulter Navios Flow Cytometer · 2010 · ref ML-79A20373
Description
Lasers: Blue Solid State: 488 nm, 55 mW, Software Controlled Red Solid State Diode: 638 nm, 50 mW, Software Controlled Violet Solid State: 405 nm, 80 mW, Software Controlled Beam-Shaping Optics: Cross cylindrical lenses 10 mm by 80 mm. Blue Laser Beam Spot Size: An elliptical spot 10 μm high by 84 μm wide Red Laser Beam Spot Size: An elliptical spot 9.6 μm high by 72 μm wide. Violet Laser Beam Spot Size: An elliptical spot 8.9 μm high by 70 μm wide. Laser Beam Separation: The laser beams are 125 μm (±12.5 μm) apart Flow cell: BioSense 150 μm x 460 rectangular channel with an integral lens, mounted with avertical (upward) flow path. Detector filters: See image Sensors: The FS sensor and the SS sensor are photodiodes. The FL sensors are photo-multiplier tubes (PMTs) that have a 200-nm to 800-nm spectral range Flow rates: Continuous pressure is applied to the sample tube based on user selected flow rates: Low (10 µL/min), Medium (30 µL/min) and High (60 µL/min) Sheath Consumption: 780mL/h Performance: Carryover: < 0.1%, Dead volume as low as 2 µL when using Beckman Coulter 12 x 75 mm polypropylene tube and adjustable probe Acquisition modes: 32 tube Multi Carousel Loader (MCL), Single tube sampling mode, Automated work list acquisition, Manual work list mode Throughput: 10000 normal leukocytes is 82 tubes/hour Scatter resolution: Resolves 0.4 micron particles from background noise using Forward Scatter, Maximum detection of up to 40 microns Fluorescence sensitivity: FITC < 107 MESF, PE < 64 MESF, PC5 < 13 MESF Acquisition rate: 25000 events per second, 90% yield Cytometer dimensions (WxHxD): 950 x 610 x 730 mm Cytometer weight: 104 kg Supply cart dimensions (WxHxD): 724 x 298 x 495 mm Supply cart weight: 30 kg PC and Software included.
Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.
Specifications
- Condition
- Good
- Year Manufactured
- 2010
- Manufacturer
- Beckman Coulter
- Model
- Coulter Navios Flow Cytometer
- Equipment weight
- 104 kg
- Equipment dimensions
- 95 × 61 × 73 cm
- Warranty
- 6 months
- Flow Cell
- BioSense 150 μm x 460 rectangular channel with an integral lens, mounted with averticalflow path.
- Flow Rates
- Continuous pressure is applied to the sample tube based on user selected flow rates: Low, Mediumand High
- Performance
- Carryover: < 0.1%, Dead volume as low as 2 µL when using Beckman Coulter 12 x 75 mm polypropylene tube and adjustable probe
- Acquisition Rate
- 25000 events per second, 90% yield
- Blue Solid State
- 488 nm, 55 mW, Software Controlled
- Cytometer Weight
- 104 kg
- Detector Filters
- See image
- Acquisition Modes
- 32 tube Multi Carousel Loader, Single tube sampling mode, Automated work list acquisition, Manual work list mode
- Scatter Resolution
- Resolves 0.4 micron particles from background noise using Forward Scatter, Maximum detection of up to 40 microns
- Sheath Consumption
- 780mL/h
- Supply Cart Weight
- 30 kg
- Violet Solid State
- 405 nm, 80 mW, Software Controlled
- Beam Shaping Optics
- Cross cylindrical lenses 10 mm by 80 mm.
- Date Of Manufacture
- 2010
- Laser Beam Separation
- The laser beams are 125 μmapart
- Red Solid State Diode
- 638 nm, 50 mW, Software Controlled
- Fluorescence Sensitivity
- FITC < 107 MESF, PE < 64 MESF, PC5 < 13 MESF
- Red Laser Beam Spot Size
- An elliptical spot 9.6 μm high by 72 μm wide.
- Blue Laser Beam Spot Size
- An elliptical spot 10 μm high by 84 μm wide
- Cytometer Dimensions Wxhxd
- 950 x 610 x 730 mm
- Violet Laser Beam Spot Size
- An elliptical spot 8.9 μm high by 70 μm wide.
- Supply Cart Dimensions Wxhxd
- 724 x 298 x 495 mm
- Throughput
- 10000 normal leukocytes is 82 tubes/hour
Shipping & Logistics
MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.
- MerkaLoop coordinates all logistics
- Shipping quoted before payment
- Ships globally
Shipping from: Netherlands
It is your responsibility to check local regulations and requirements for the handling, acceptance, and servicing of secondhand and new equipment.
contact MerkaLoop about this equipment
Similar Equipment

Pre-owned · Good
Thermo Scientific Attune NxT AFC2 Flow Cytometer with CytKick Max (3 lasers, 11 colours, 13 detectors)
£39,600

Pre-owned · Good
BD FACSCalibur Flow Cytometer
£1,200

Pre-owned · Good
BD FACS Lyse Wash Assistant
€2,749

Pre-owned · Good · 2015
Acea Biosciences NovoCyte 2000 Flow Cytometer
€38,499