BD Becton Dickinson FACSCanto II Flow Cytometer
BD · Becton Dickinson FACSCanto II Flow Cytometer · 2007 · ref ML-938FB865
Description
The FACSCanto II system is an easy-to-use benchtop analyzer that delivers proven performance, accuracy, and high-quality results. The FACSCanto II can be configured with two or three lasers to detect up to eight colors. It features many innovations, including a true fixed alignment flow cell to minimize startup time and improve reproducibility. The optical system maximizes signal detection and increases sensitivity and resolution for each color in a multicolor assay. These and other capabilities make the BD FACSCanto II ideal for today’s busy clinical lab, providing a high degree of automation and quality control. With optimal reproducibility, the FACSCanto II system reduces hands-on technician time and costs associated with repeat testing. Lasers: 405-nm solid state diode, 30-mW fiber power output 488-nm solid state, 20-mW laser output 633-nm HeNe, 17-mW laser output Laser Configuration: Spatially separated beams with 9 x 65- μm elliptical spots Optical Alignment Procedure: Fixed, no operator alignment required Flow Cell: 180 x 430-μm rectangular quartz flow cell Collection Optics: Optical-gel coupled 1.2 NA lens FSC Resolution: 1.0 μm SSC Resolution: 0.5 μm Fluorescence Detector Design: Reflective optics with single transmission filter in front of each PMT FSC Detector: Photodiode with 488/10 BP SSC Detector: PMT with 488/10 BP Fluorescence Detectors: 8 PMTs in 4-2-2 configuration Violet Laser Dyes: Pacific Blue, AmCyan (455, 488 nm) Blue Laser Dyes: FITC, PE, PerCP or PerCP-Cy 5.5, PE-Cy 7 (525, 575, 678 or 695, 785 nm) Red Laser Dyes: APC, APC-Cy7 (660, 785 nm) Detector Bands: Violet Laser: 450/50; 502 to 525 nm Blue Laser: 530/30; 585/42; >670; 780/60 nm Red Laser: 660/20; 780/60 nm Fluorescence Threshold Sensitivities: FITC <100 MESF; PE <50 MESF Max Particle Size: 50 μm Sample Flow Rate: 10 μL/min to 120 μL/min Sample Acquisition Rate: 10,000 events/second, 6 compensated fluorescence parameters and 2 scatter parameters Sample Dead Volume: 30 μL (BD Falcon tubes 12 x 75-mm) Dimensions (DxWxH): Cytometer: 610 x 910 x 640 mm Fluidics cart: 610 x 790 x 640 mm Weight: Cytometer: 145 kg Fluidics cart: 51 kg
Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.
Specifications
- Condition
- Good
- Year Manufactured
- 2007
- Manufacturer
- BD
- Model
- Becton Dickinson FACSCanto II Flow Cytometer
- Equipment weight
- 145 kg
- Equipment dimensions
- 91 × 64 × 61 cm
- Warranty
- 6 months
- Cytometer
- 610 x 910 x 640 mm
- Flow Cell
- 180 x 430-μm rectangular quartz flow cell
- Fsc Detector
- Photodiode with 488/10 BP
- Ssc Detector
- PMT with 488/10 BP
- Fluidics Cart
- 610 x 790 x 640 mm
- Fsc Resolution
- 1.0 μm
- Red Laser Dyes
- APC, APC-Cy7
- Ssc Resolution
- 0.5 μm
- Blue Laser Dyes
- FITC, PE, PerCP or PerCP-Cy 5.5, PE-Cy 7
- Sample Flow Rate
- 10 μL/min to 120 μL/min
- Collection Optics
- Optical-gel coupled 1.2 NA lens
- Max Particle Size
- 50 μm
- Violet Laser Dyes
- Pacific Blue, AmCyan
- Sample Dead Volume
- 30 μL
- Date Of Manufacture
- 2007
- Laser Configuration
- Spatially separated beams with 9 x 65-
- Fluorescence Detectors
- 8 PMTs in 4-2-2 configuration
- Sample Acquisition Rate
- 10,000 events/second, 6 compensated
- Optical Alignment Procedure
- Fixed, no operator alignment required
- Fluorescence Detector Design
- Reflective optics with single transmission filter in front of each PMT
- Fluorescence Threshold Sensitivities
- FITC <100 MESF; PE <50 MESF
- Red Laser
- 660/20; 780/60 nm
- Blue Laser
- 530/30; 585/42; >670; 780/60 nm
- Violet Laser
- 450/50; 502 to 525 nm
Shipping & Logistics
MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.
- MerkaLoop coordinates all logistics
- Shipping quoted before payment
- Ships globally
Shipping from: Netherlands
It is your responsibility to check local regulations and requirements for the handling, acceptance, and servicing of secondhand and new equipment.
contact MerkaLoop about this equipment
Similar Equipment

Pre-owned · Good
Thermo Scientific Attune NxT AFC2 Flow Cytometer with CytKick Max (3 lasers, 11 colours, 13 detectors)
£39,600

Pre-owned · Good
BD FACSCalibur Flow Cytometer
£1,200

Pre-owned · Good
BD FACS Lyse Wash Assistant
€2,749

Pre-owned · Good · 2015
Acea Biosciences NovoCyte 2000 Flow Cytometer
€38,499