

Beckman Coulter CytoFLEX Flow Cytometer
Beckman Coulter · CytoFLEX · ref ML-DA20D057
Description
The CytoFLEX Flow Cytometer has a unique flow cell design and integrated optics. The innovative Wavelength Division Multiplexing (WDM) detection module includes solid-state, high efficiency, low-noise detectors for excellent performance. The revolutionary system presents optimal excitation and emission, minimizing light loss and maximizing sensitivity. This means that you can easily detect dim populations in your sample and all with an easy to use software interface. At 40.6 by 40.5 by 33 cm (H by W by D) and less than 22 kg, the compact size and light weight mean that you can take the instrument wherever it is needed, including inside a laminar flow or biosafety hood. The CytoFLEX Flow Cytometer’s superior sensitivity and resolution throughout all configurations give it the edge over other cytometry systems four times its size. Features: Model: Beckman Coulter CytoFLEX (2019; lightly used, ~1–2 times/week) Configuration: 2-laser (Blue & Red) with 4 active channels (upgradeable to 3 lasers, 13 channels) Filters/Channels: FITC 525/40, PE 585/42, APC 660/10, APC-A750 763/43 Lasers/Detectors: Solid-state diode lasers with APD detectors (7 decades dynamic range) Sample input: 5 mL tubes or 96-well plates (standard and deep-well) Performance: Adjustable flow rate (10–240 µL/min), up to 30k events/second Sensitivity: MESF: FITC 30, PE 10 Service history: Annual PM performed by Beckman Coulter every year; half-yearly maintenance has been done every 6 months
Pre-owned equipment sold by a third-party reseller through MerkaLoop. Ships directly from the reseller.
Specifications
- Condition
- Good
- Manufacturer
- Beckman Coulter
- Model
- CytoFLEX
- Equipment weight
- 65 kg
- Equipment dimensions
- 69 × 61 × 60 cm
- Warranty
- 1 month
- Performance
- Adjustable flow rate, up to 30k events/second
- Sensitivity
- MESF: FITC 30, PE 10
- Sample Input
- 5 mL tubes or 96-well plates
- Configuration
- 2-laserwith 4 active channels
- Filters Channels
- FITC 525/40, PE 585/42, APC 660/10, APC-A750 763/43
- Lasers Detectors
- Solid-state diode lasers with APD detectors
Service History
Annual PM performed by Beckman Coulter every year; half-yearly maintenance has been done every 6 months
Shipping & Logistics
MerkaLoop coordinates all logistics. Timelines depend on seller location and your destination.
- MerkaLoop coordinates all logistics
- Shipping quoted before payment
- Ships globally
Shipping from: Netherlands
It is your responsibility to check local regulations and requirements for the handling, acceptance, and servicing of secondhand and new equipment.
contact MerkaLoop about this equipment
Similar Equipment

Pre-owned · Good
Thermo Scientific Attune NxT AFC2 Flow Cytometer with CytKick Max (3 lasers, 11 colours, 13 detectors)
£39,600

Pre-owned · Good
BD FACSCalibur Flow Cytometer
£1,200

Pre-owned · Good
BD FACS Lyse Wash Assistant
€2,749

Pre-owned · Good · 2015
Acea Biosciences NovoCyte 2000 Flow Cytometer
€38,499